Battery Harness with Fuse for DCM100-01
Part #FC01
MFG #FC01
$40.00 / ea
This FC01 Maretron Battery Harness with Fuse is included with the DCM100 Direct Current/ Battery Monitor. Connected as the power cable for the DCM100 and also used as a battery sense cable.
Included with the DCM100
For Powering:
- Yellow Wire: One end to pin #7 (VPWR-) on the DCM100 and other end to vessel ground (Note: The terminal should either be at the same voltage as pin #6 (VSENS-) or less).
- Red Wire: First end to pin #8 (VPWR+) on the DCM100 and other end to source of 9-32 VDC power (Note: This wire may or may not be connected to the same place as the red wire from the Battery Sense Cable).
For Battery Sensing:
- Yellow Wire: One end to pin #6 (VSENS-) on the DCM100 and other end to negative terminal of the battery or DC source (May or may not be same as vessel ground; should either be at the same voltage as pin #7 (VPWR-) or more).
- Red Wire: First end to pin #5 (VSENS+) on the DCM100 and other end to positive terminal of battery or DC source.
FC01 cables are shipped with 1 Ampere fuses installed. This is the largest amperage fuses recommended; any larger could cause damage to the unit.
- Brand: MaretronExterior Color: WhiteConnector: Bare WireExterior Color: WhiteCountry of Origin: USACable-Length: 1 m (3.3')